A water quality survey measures physical, chemical, and biological indicators in aquatic environments such as rivers, ponds, lakes, and waterways to evaluate their condition. By examining water temperature, transparency, pH, electrical conductivity, dissolved oxygen, chemical oxygen demand, nitrogen, phosphorus, and other parameters, it is possible to discuss the characteristics of a water body and the degree of pollution.
Water quality is affected by surrounding land use, rainfall, flow rate, season, air temperature, aquatic plants, bottom sediment, and human activities. Therefore, it is important not to judge water quality from a single measurement but to evaluate multiple parameters together.
For example, when dissolved oxygen is low while COD and nutrient concentrations are high, the effects of organic matter inflow or eutrophication may be involved. On the other hand, high electrical conductivity indicates a large amount of dissolved ions, but possible causes include domestic wastewater, agricultural land, geology, and seawater influence.
This article assumes a basic water quality survey of rivers, ponds, or waterways conducted at school or university and presents an introduction, safety notes, result items, sample experimental values, calculations, sources of error, example results, and discussion examples.
Note:
This article is a study reference for preparing biology and environmental science laboratory reports. The values for water temperature, pH, dissolved oxygen, COD, nitrogen, phosphorus, and other parameters are illustrative examples and are not actual measurements from a specific river or pond.
Collect water only at safe locations with permission from the school, facility, or land manager. Do not approach flooded areas, rapid currents, deep water, restricted areas, or slippery embankments.
Avoid working alone when collecting samples, and use a life jacket, gloves, boots, or other protective equipment when necessary.
Do not drink collected water or allow it to contact wounds or eyes. Wash your hands after the survey.
When using reagents, follow the instructions, safety data sheets, and directions of the supervising instructor. Do not return used reagents or test solutions to the sampling site.
Calibrate pH meters, dissolved oxygen meters, and conductivity meters before measurement, and rinse electrodes thoroughly between samples.
Basics of Water Quality Surveys
Water Temperature
Water temperature affects the activity of aquatic organisms, dissolved oxygen levels, and chemical reaction rates. In general, oxygen becomes less soluble in water as temperature increases.
pH
pH indicates the acidity or alkalinity of water. It is affected by the geology of the water body, photosynthesis, respiration, decomposition of organic matter, and wastewater.
Electrical Conductivity
Electrical conductivity is an indicator of the amount of ions dissolved in water. Higher values generally indicate greater amounts of salts and inorganic ions.
Dissolved Oxygen
Dissolved oxygen is the amount of oxygen dissolved in water. It is required for respiration by aquatic organisms and may decrease where decomposition of organic matter is active.
COD
COD is an indicator of the amount of oxygen required to chemically oxidize readily oxidizable substances in water. A higher value may indicate a greater load of organic matter and other substances.
Nitrogen and Phosphorus
Nitrate nitrogen, ammonium nitrogen, phosphate phosphorus, and similar compounds serve as nutrients for aquatic plants and algae. Excessive concentrations can promote algal growth and eutrophication.
Main Items to Record in the Results
- Survey date
- Survey time
- Survey site
- Weather
- Rainfall up to the previous day
- Air temperature
- Water temperature
- Water depth
- Flow velocity
- River width or size of the water body
- Water color
- Odor
- Turbidity
- Transparency
- pH
- Electrical conductivity
- Dissolved oxygen concentration
- Dissolved oxygen saturation
- COD
- Nitrate nitrogen
- Nitrite nitrogen
- Ammonium nitrogen
- Phosphate phosphorus
- Chloride ions
- Hardness
- Suspended matter
- Bottom sediment condition
- Presence of aquatic plants
- Presence of algae
- Presence of aquatic organisms
- Surrounding land use
- Presence of drainage outlets
- Replicate measurements
- Mean
- Standard deviation
Sample Experimental Values
Overview of Survey Sites
| Site | Environment | Surroundings |
|---|---|---|
| Site A | Upstream river | Heavily wooded, fast flow |
| Site B | Near residential area | Embanked, moderate flow |
| Site C | Pond | Little flow, many aquatic plants |
Sample Field Observations
| Item | Site A | Site B | Site C |
|---|---|---|---|
| Weather | Sunny | Sunny | Sunny |
| Air temperature | 22.8°C | 24.1°C | 25.3°C |
| Water temperature | 17.6°C | 20.8°C | 23.9°C |
| Water depth | 28 cm | 42 cm | 65 cm |
| Flow velocity | 0.42 m/s | 0.18 m/s | Less than 0.01 m/s |
| Transparency | High | Moderate | Low |
| Odor | Almost none | Slight earthy odor | Algal odor |
| Bottom sediment | Rock and sand | Sand and mud | Mud |
Water Quality Measurements
| Item | Site A | Site B | Site C |
|---|---|---|---|
| pH | 7.2 | 7.5 | 8.3 |
| Electrical conductivity | 78 µS/cm | 215 µS/cm | 328 µS/cm |
| Dissolved oxygen | 9.4 mg/L | 7.1 mg/L | 5.2 mg/L |
| Dissolved oxygen saturation | 95% | 78% | 63% |
| COD | 1.4 mg/L | 3.8 mg/L | 7.2 mg/L |
| Nitrate nitrogen | 0.35 mg/L | 1.20 mg/L | 0.82 mg/L |
| Ammonium nitrogen | 0.03 mg/L | 0.18 mg/L | 0.42 mg/L |
| Phosphate phosphorus | 0.015 mg/L | 0.080 mg/L | 0.160 mg/L |
| Chloride ions | 8 mg/L | 24 mg/L | 31 mg/L |
Sample Replicate Measurements
| Replicate | Site B pH | Site B DO (mg/L) | Site B COD (mg/L) |
|---|---|---|---|
| 1 | 7.4 | 7.0 | 3.7 |
| 2 | 7.5 | 7.2 | 3.9 |
| 3 | 7.6 | 7.1 | 3.8 |
| Mean | 7.5 | 7.1 | 3.8 |
Sample Values Before and After Rainfall
| Item | Before rainfall | After rainfall |
|---|---|---|
| Relative turbidity | 1.0 | 3.6 |
| Electrical conductivity | 215 µS/cm | 168 µS/cm |
| COD | 3.8 mg/L | 5.1 mg/L |
| Nitrate nitrogen | 1.20 mg/L | 1.65 mg/L |
Calculation Methods
Mean
If dissolved oxygen at Site B is 7.0, 7.2, and 7.1 mg/L, the calculation is as follows.
Mean = (7.0 + 7.2 + 7.1) ÷ 3
= 7.1 mg/L
Standard Deviation
s = √{Σ(xi − x̄)2 ÷ (n − 1)}
≈ 0.10 mg/L
Coefficient of Variation
Coefficient of variation (%) = Standard deviation ÷ Mean × 100
= 0.10 ÷ 7.1 × 100
≈ 1.4%
Difference Between Sites
The difference in COD between Sites A and C is calculated as follows.
COD difference = 7.2 − 1.4
= 5.8 mg/L
Percentage Increase
The percentage increase in COD at Site C relative to Site A is calculated as follows.
Increase (%) = (Site C − Site A) ÷ Site A × 100
= (7.2 − 1.4) ÷ 1.4 × 100
≈ 414%
Dissolved Oxygen Saturation
If saturated dissolved oxygen at the measurement temperature is 9.1 mg/L and the measured value is 7.1 mg/L, the calculation is as follows.
DO saturation (%) = Measured DO ÷ Saturated DO × 100
= 7.1 ÷ 9.1 × 100
≈ 78%
Concentration of a Diluted Sample
If a sample is diluted fivefold and the measured concentration is 1.44 mg/L, the calculation is as follows.
Original sample concentration = Measured value × Dilution factor
= 1.44 × 5
= 7.2 mg/L
Simple Estimate of Flow Rate
If river width is 2.0 m, mean depth is 0.30 m, and mean flow velocity is 0.42 m/s, the calculation is as follows.
Cross-sectional area = River width × Mean depth
= 2.0 × 0.30 = 0.60 m²
Flow rate = Cross-sectional area × Mean flow velocity
= 0.60 × 0.42
= 0.252 m³/s
Simple Calculation of Substance Load
If nitrate nitrogen concentration is 0.35 mg/L and flow rate is 0.252 m³/s, the calculation is as follows.
1 m³ = 1000 L
Load = Concentration × Flow rate
= 0.35 mg/L × 252 L/s
= 88.2 mg/s
Nutrient Ratio
If nitrate nitrogen at Site C is 0.82 mg/L and phosphate phosphorus is 0.160 mg/L, the mass ratio is as follows.
N:P = 0.82 ÷ 0.160
≈ 5.1:1
This ratio is a simple mass ratio based on the measured chemical forms and does not directly determine nutrient limitation in the entire ecosystem.
Main Sources of Error
| Source of error | Effect on results | Improvement |
|---|---|---|
| Variation in sampling location | Differences in flow and depth affect results | Record the location and sample at the same place |
| Different sampling depths | Values differ between surface and bottom layers | Standardize sampling depth |
| Different sampling times | Water temperature, pH, and DO vary during the day | Compare samples collected at the same time of day |
| Rainfall effects | Turbidity, flow, and nutrients change | Record recent rainfall |
| Container contamination | Ion and nutrient concentrations may appear high | Use clean containers |
| Residual detergent in containers | Affects COD and phosphorus concentration | Wash and rinse thoroughly |
| Bottom mud mixed into sample | Increases turbidity, COD, and phosphorus | Sample without disturbing the bottom |
| Long sample storage time | Biological activity changes components | Measure promptly |
| Improper storage temperature | Reactions and microbial activity proceed | Store under specified cool, dark conditions |
| Insufficient pH meter calibration | Causes systematic measurement error | Calibrate with standard solutions |
| Insufficient electrode rinsing | Effects of the previous sample remain | Rinse with purified water between samples |
| Insufficient electrode stabilization time | Value is recorded before stabilization | Wait until the reading stabilizes |
| Insufficient temperature correction | Causes errors in pH, EC, and DO | Check temperature compensation functions or correction formulas |
| Air bubbles during DO measurement | May produce an artificially high value | Remove bubbles around the electrode |
| Insufficient stirring during DO measurement | Oxygen near the sensor surface becomes depleted | Maintain the flow specified for the instrument |
| Error in reagent volume | Shifts COD and nutrient concentrations | Use an appropriate pipette |
| Different reaction times | Changes color intensity | Standardize timing with a timer |
| Different reaction temperatures | Changes absorbance or color | React at the specified temperature |
| Visual color comparison | Creates observer variation | Use the same lighting and have multiple people check |
| Light scattering from turbidity | Colorimetric values may appear high | Filter or apply blank correction when appropriate |
| Outside measurement range | Concentration cannot be determined accurately | Dilute appropriately and remeasure |
| Error recording dilution factor | Converted concentration becomes incorrect | Record dilution procedures |
| Insufficient blank correction | Includes values originating from reagents or containers | Measure a reagent blank |
| Insufficient distance for flow measurement | Increases error in mean flow velocity | Use sufficient distance and replicates |
| Wind effects on a float | Distorts surface velocity | Measure repeatedly under low-wind conditions |
| Insufficient estimation of mean depth | Distorts flow-rate calculations | Measure depth at multiple points |
| Too few replicates | Random error cannot be evaluated | Measure the same sample multiple times |
| Different conditions among sites | Simple comparison may be inappropriate | Record flow, sunlight, sediment, and other conditions |
| Ignoring seasonal differences | Temporary values are overgeneralized | Conduct surveys in different seasons |
| Evaluation using only one indicator | Water quality may be misinterpreted | Evaluate multiple parameters together |
Example Results
Water temperature, pH, electrical conductivity, dissolved oxygen, COD, nitrogen, and phosphorus were measured at Site A in the upper river, Site B near a residential area, and Site C in a slow-flowing pond.
Water temperature was 17.6°C at Site A, 20.8°C at Site B, and 23.9°C at Site C, with the highest temperature at the slow-flowing Site C.
pH was 7.2 at Site A, 7.5 at Site B, and 8.3 at Site C.
Electrical conductivity was 78 µS/cm at Site A, 215 µS/cm at Site B, and 328 µS/cm at Site C, with the highest value at Site C.
Dissolved oxygen concentration was 9.4 mg/L at Site A, 7.1 mg/L at Site B, and 5.2 mg/L at Site C, with the lowest value at Site C.
COD was 1.4 mg/L at Site A, 3.8 mg/L at Site B, and 7.2 mg/L at Site C.
Phosphate phosphorus was 0.015 mg/L at Site A, 0.080 mg/L at Site B, and 0.160 mg/L at Site C, increasing toward Site C.
Overall, Site A had high dissolved oxygen and low COD and nutrient concentrations. In contrast, Site C had low dissolved oxygen and high COD, electrical conductivity, ammonium nitrogen, and phosphate phosphorus.
Discussion Example
In this survey, water temperature, pH, electrical conductivity, dissolved oxygen, COD, nitrogen, phosphorus, and other parameters were measured at three sites with different environmental conditions, and differences in water quality were compared.
Site A was located in the upper river and had a water temperature of 17.6°C, dissolved oxygen of 9.4 mg/L, and COD of 1.4 mg/L.
The high dissolved oxygen at Site A may be explained by the low water temperature, rapid flow that promotes aeration at the water surface, and relatively low organic matter loading.
In general, oxygen dissolves more readily in colder water. In riffles and flowing water with drops, contact between water and air also promotes oxygen supply.
Site A had the lowest COD among the three sites, and nitrate nitrogen, ammonium nitrogen, and phosphate phosphorus were also low.
These findings suggest that Site A had relatively little inflow of organic matter and nutrients and maintained comparatively good water quality.
Site B was near a residential area and had a water temperature of 20.8°C, electrical conductivity of 215 µS/cm, and COD of 3.8 mg/L.
The higher electrical conductivity than at Site A suggests that the amount of dissolved ions in the water had increased.
Possible causes include differences in local geology as well as road runoff, inflow from residential areas, and fertilizer components. However, electrical conductivity alone cannot identify the types of ions, so it should be interpreted together with measurements of chloride ions, nitrogen compounds, and other substances.
Nitrate nitrogen at Site B was 1.20 mg/L, the highest among the three sites.
Possible reasons for the high nitrate nitrogen include runoff from residential or agricultural land and inflow of nitrate produced in soil.
Ammonium nitrogen, however, was lower than at Site C. At Site B, where water was flowing and oxygen was relatively abundant, ammonium may have been more readily converted to nitrate through nitrification.
Site C was a slow-flowing pond with a water temperature of 23.9°C, dissolved oxygen of 5.2 mg/L, and COD of 7.2 mg/L.
The low dissolved oxygen at Site C may have resulted from high water temperature, limited flow, and oxygen consumption caused by decomposition of bottom sediment and organic matter.
Site C had an algal odor and low transparency. Its pH was 8.3, the highest among the three sites.
When photosynthesis by algae and aquatic plants is active during the day, carbon dioxide in the water is consumed and pH may rise.
At night, however, photosynthesis stops while respiration continues to consume oxygen, so dissolved oxygen may decrease further.
Therefore, a more detailed evaluation of Site C should include measurements not only during the day but also in the early morning and at night to examine daily variation.
Site C showed high ammonium nitrogen at 0.42 mg/L and phosphate phosphorus at 0.160 mg/L.
In slow-flowing waters, fallen leaves, algae, and dead aquatic organisms may accumulate on the bottom, and decomposition can release nitrogen and phosphorus into the water.
When oxygen is depleted near the bottom, phosphorus may also be released more readily from sediment, potentially further promoting algal growth.
Because COD at Site C was about 5.1 times that at Site A, the amount of readily oxidizable substances was considered greater.
However, COD is affected not only by organic matter but also by some inorganic reducing substances, so the cause of organic pollution cannot be determined from COD alone.
Examining water turbidity and color, bottom sediment, chlorophyll concentration, biochemical oxygen demand, and other parameters would allow a more detailed assessment.
After rainfall, turbidity, COD, and nitrate nitrogen increased at Site B, while electrical conductivity decreased.
The increases in turbidity and COD were likely caused by inflow of soil particles and organic matter in rainwater runoff.
The decrease in electrical conductivity may have resulted from temporary dilution of river water by rainwater with a low ion concentration.
At the same time, the increase in nitrate nitrogen suggests that rainfall may have washed nitrogen compounds from surrounding soil and land surfaces into the water.
Thus, rainfall causes both dilution and material inflow, so different parameters may change in different directions.
In replicate measurements, mean dissolved oxygen at Site B was 7.1 mg/L, the standard deviation was 0.10 mg/L, and the coefficient of variation was approximately 1.4%.
Because variation among replicates was relatively small, measurement reproducibility for the same sample was generally good.
However, aquatic environments themselves have spatial and temporal heterogeneity. Even small differences in sampling location or depth may produce different values, so it is necessary to compare samples from multiple sites and times in addition to repeating instrument measurements.
The results of this survey indicate that Site A had low water temperature, high dissolved oxygen, low COD, and low nutrient concentrations, and therefore had relatively good water quality among the three sites.
Site B had higher electrical conductivity and nitrate nitrogen than Site A, suggesting possible effects of surrounding human activity and land use.
Site C showed high water temperature, low dissolved oxygen, high COD, and high phosphorus concentration, suggesting stronger effects of organic matter accumulation and eutrophication.
However, this survey was conducted during a limited period on a single day and therefore does not fully reflect seasonal or daily variation.
Future studies could investigate the causes of water quality changes in greater detail by combining surveys in spring, summer, autumn, and winter, comparisons before and after rainfall, early-morning and daytime measurements, and biological community surveys.
Discussion Example When Dissolved Oxygen Was Low
Possible causes of low dissolved oxygen include increased water temperature, stagnant flow, oxygen consumption during organic matter decomposition, respiration by aquatic organisms, and reducing conditions in bottom sediment. Values should be compared between early morning and daytime to examine daily variation.
Discussion Example When pH Was High
A high pH may result from consumption of carbon dioxide by photosynthesis of algae and aquatic plants. Because pH tends to rise during sunny daytime conditions, it should be evaluated together with measurement time, algal abundance, and dissolved oxygen.
Discussion Example When COD Was High
High COD may indicate a large amount of readily oxidizable organic matter or reducing substances in the water. Possible causes include domestic wastewater, fallen leaves, algae, and resuspension of bottom sediment. Turbidity, odor, nutrients, and bottom sediment conditions should also be examined.
Discussion Example When Electrical Conductivity Was High
High electrical conductivity indicates a large amount of dissolved ions in the water. Possible causes include domestic wastewater, fertilizer, road runoff, geology, and saltwater influence. Because electrical conductivity alone cannot identify individual components, analysis of specific ions is necessary.
Discussion Example When Differences Between Sites Were Small
If differences among sites were small, the sites may have belonged to the same water system with rapid water exchange. Similar sampling times and recent rainfall conditions may also have contributed. The survey should be repeated under different seasonal and flow conditions.
Summary
Water quality surveys evaluate aquatic environments by combining measurements such as water temperature, pH, electrical conductivity, dissolved oxygen, COD, nitrogen, and phosphorus.
Sites with fast flow and low water temperature tend to have higher dissolved oxygen.
In slow-flowing waters, organic matter and nutrients may accumulate, resulting in increased COD and decreased dissolved oxygen.
Rainfall, season, time of day, and surrounding land use can greatly affect measured values.
It is important not to determine water quality from a single parameter, but to interpret field observations, multiple water quality indicators, replicate measurements, and long-term surveys together.