The Kirchhoff’s laws experiment examines a circuit containing multiple resistors and power sources by measuring the relationships among currents at junctions and voltages around closed loops, confirming that conservation of charge and conservation of energy hold.
In simple series or parallel circuits, currents and voltages can be found relatively easily using Ohm’s law alone. In circuits with multiple branches or sources, however, the current in each branch must be treated as an unknown and simultaneous equations must be constructed using Kirchhoff’s first and second laws.
This article assumes a DC circuit in which two closed loops share one common branch and presents the introduction, precautions, result items, sample experimental values, calculations, sources of error, an example results section, and discussion examples.
Note:
This article is a study reference for discussing results obtained in physics experiments at schools and universities. The experimental conditions and measured values shown here are illustrative examples and are not actual measurements.
Always turn off the power before changing circuit wiring. Connecting an ammeter directly in parallel with a power source creates a short circuit and may damage the meter or power supply. Check resistor power ratings, source polarity, and instrument measurement ranges, and follow the instructions in your school’s laboratory manual and those of your instructor or TA.
- What Are Kirchhoff’s Laws?
- Main Items to Record in the Results
- Sample Circuit and Experimental Conditions
- Sample Experimental Values
- Calculation Method
- Constructing the Current Equation from the First Law
- Equation for the Left Loop
- Equation for the Right Loop
- Solving the Simultaneous Equations
- Voltage Drop Across Each Resistor
- Residual for the First Law
- Percentage Difference for the First Law
- Residual for the Second Law
- Relative Error from the Theoretical Value
- Main Sources of Error
- Example of How to Write the Results
- Points to Connect to the Discussion
- Discussion Example
- Summary
What Are Kirchhoff’s Laws?
Kirchhoff’s laws consist of the first law, which describes the relationship among currents at a junction, and the second law, which describes the relationship among voltages in a closed loop.
Kirchhoff’s First Law
The sum of currents flowing into a junction equals the sum of currents flowing out of the junction.
ΣIin = ΣIout
For example, if current I1 flows into a junction while I2 and I3 flow out, then:
I1 = I2 + I3
This means that charge does not continuously accumulate at the junction and is based on conservation of charge.
Kirchhoff’s Second Law
When traversing any closed loop, the algebraic sum of electromotive forces and voltage drops is zero.
ΣV = 0
If the source emf is E and the voltage drop across a resistor is IR, a simple closed loop can be written as:
E − IR = 0
This shows that after going around a complete loop and returning to the starting point, the electric potential returns to its original value. It is based on conservation of energy.
Sign Conventions
- The current direction may be assumed arbitrarily before beginning the calculation.
- Moving through a resistor in the assumed current direction decreases the potential by IR.
- Moving through a resistor opposite to the current direction increases the potential by IR.
- Moving through a source from its negative to positive terminal increases the potential by E.
- Moving through a source from its positive to negative terminal decreases the potential by E.
If a calculated current is negative, the actual current flows opposite to the direction initially assumed.
Main Items to Record in the Results
- EMF or terminal voltage of each power source
- Nominal resistance of each resistor
- Measured resistance of each resistor
- Circuit diagram and assumed current direction in each branch
- Current in each branch
- Sum of currents entering each junction
- Sum of currents leaving each junction
- Voltage across each resistor
- Sum of EMFs in each closed loop
- Sum of voltage drops in each closed loop
- Residual for the first law
- Residual for the second law
- Relative error between theoretical and measured currents
- Relative error between theoretical and measured voltages
- Resistor heating and changes in source voltage
- Measurement ranges and resolutions of ammeters and voltmeters
Sample Circuit and Experimental Conditions
In this example, three branches are connected in parallel between an upper junction A and a lower junction B.
- Left branch: source E1 = 6.00 V and resistor R1 = 100 Ω
- Center branch: resistor R3 = 150 Ω
- Right branch: source E2 = 3.00 V and resistor R2 = 220 Ω
The current directions are assumed so that I1 in the left branch and I2 in the right branch flow into junction A, while I3 flows from A to B through the center branch.
| Item | Sample Condition |
|---|---|
| Source E1 | 6.00 V |
| Source E2 | 3.00 V |
| Resistor R1 | 100 Ω |
| Resistor R2 | 220 Ω |
| Resistor R3 | 150 Ω |
| Resistor tolerance | ±5% |
| Ammeter | Digital ammeter |
| Voltmeter | Digital voltmeter |
| Room temperature | 23 ℃ |
Sample Experimental Values
Comparison of Theoretical and Measured Values
| Measurement | Theoretical Value | Measured Value | Relative Error |
|---|---|---|---|
| I1 | 30.4 mA | 30.1 mA | 0.99% |
| I2 | 2.01 mA | 2.05 mA | 1.99% |
| I3 | 32.4 mA | 32.1 mA | 0.93% |
| VR1 | 3.04 V | 3.01 V | 0.99% |
| VR2 | 0.442 V | 0.451 V | 2.04% |
| VR3 | 4.86 V | 4.82 V | 0.82% |
Verification of the First Law
| Item | Measured Value |
|---|---|
| Current entering junction A, I1 + I2 | 32.15 mA |
| Current leaving junction A, I3 | 32.10 mA |
| Difference | 0.05 mA |
| Percentage difference | Approx. 0.16% |
Second Law for the Left Loop
| Item | Measured Value |
|---|---|
| Source E1 | 6.00 V |
| Voltage drop across R1 | 3.01 V |
| Voltage drop across R3 | 2.98 V |
| E1 − VR1 − VR3 | 0.01 V |
In this table, 2.98 V is used as an example of the voltage measured directly across the center branch within the loop. Depending on the measurement points and source polarity, the sign of each voltage should be defined according to the circuit diagram.
Second Law for the Right Loop
| Item | Measured Value |
|---|---|
| Source E2 | 3.00 V |
| Voltage drop across R2 | 0.45 V |
| Potential difference across common branch | 2.54 V |
| E2 − VR2 − 2.54 | 0.01 V |
In an experiment, clearly state which terminal-to-terminal voltage was taken as positive and assign signs according to the chosen direction around the loop.
Example Repeated Measurements
| Trial | I1 (mA) | I2 (mA) | I3 (mA) | I1 + I2 − I3 (mA) |
|---|---|---|---|---|
| 1 | 30.1 | 2.05 | 32.1 | 0.05 |
| 2 | 30.0 | 2.08 | 32.0 | 0.08 |
| 3 | 30.2 | 2.03 | 32.2 | 0.03 |
Calculation Method
Constructing the Current Equation from the First Law
If I1 and I2 are assumed to enter junction A and I3 to leave it, then:
I1 + I2 = I3
Equation for the Left Loop
Suppose the left loop is traversed from the negative to positive terminal of the source and through the resistors in the current direction.
E1 − R1I1 − R3I3 = 0
Substituting the numerical values gives:
6.00 − 100I1 − 150I3 = 0
Equation for the Right Loop
E2 − R2I2 − R3I3 = 0
Substituting the numerical values gives:
3.00 − 220I2 − 150I3 = 0
Solving the Simultaneous Equations
From the first law, let I3 = I1 + I2, and substitute this into the two loop equations.
6.00 − 100I1 − 150(I1 + I2) = 0
3.00 − 220I2 − 150(I1 + I2) = 0
Rearranging gives the following simultaneous equations:
250I1 + 150I2 = 6.00
150I1 + 370I2 = 3.00
Solving them gives the following sample theoretical values:
I1 ≈ 30.4 mA
I2 ≈ 2.01 mA
I3 = I1 + I2 ≈ 32.4 mA
Voltage Drop Across Each Resistor
VR1 = R1I1
= 100 × 0.0304
= 3.04 V
VR2 = R2I2
= 220 × 0.00201
= 0.442 V
VR3 = R3I3
= 150 × 0.0324
= 4.86 V
Residual for the First Law
If the measured values are I1 = 30.1 mA, I2 = 2.05 mA, and I3 = 32.1 mA:
Residual = I1 + I2 − I3
= 30.1 + 2.05 − 32.1
= 0.05 mA
Percentage Difference for the First Law
Percentage difference (%) = |I1 + I2 − I3| / I3 × 100
= 0.05 / 32.1 × 100
= approx. 0.16%
Residual for the Second Law
For the left loop, if the source voltage is 6.00 V and the two voltage drops are 3.01 V and 2.98 V:
Residual = 6.00 − 3.01 − 2.98
= 0.01 V
Relative Error from the Theoretical Value
If the theoretical value of I1 is 30.4 mA and the measured value is 30.1 mA:
Relative error (%) = |measured value − theoretical value| / theoretical value × 100
= |30.1 − 30.4| / 30.4 × 100
= approx. 0.99%
Main Sources of Error
| Source of Error | Effect on Measurement | Likely Trend in Results | Improvement |
|---|---|---|---|
| Resistor tolerance | Actual resistance differs from nominal value | Systematic difference between theoretical and measured currents | Use measured resistance values in calculations |
| Internal resistance of power source | Terminal voltage under load falls below nominal value | Measured current becomes smaller than theoretical value | Measure terminal voltage while current is flowing |
| Internal resistance of ammeter | Increases resistance of measured branch | Current in that branch decreases | Use an ammeter with low internal resistance |
| Internal resistance of voltmeter | Creates a parallel current path | Slightly affects branch currents and junction-current relationships | Use a voltmeter with high internal resistance |
| Wire and contact resistance | Creates voltage drops not shown in the circuit diagram | Increases loop-voltage residual | Use short wires and secure terminals |
| Poor contact | Contact resistance becomes unstable | Current changes over time | Clean terminals and clips and check wiring |
| Resistor heating | Resistance changes during measurement | Current changes over time | Measure briefly within rated power and cool if necessary |
| Power-supply voltage variation | Actual voltage differs from emf used in theory | Currents in all branches shift together | Record source voltage at each measurement |
| Instrument resolution | Small currents and residuals cannot be read accurately | Relative error becomes large in low-current branches | Select an appropriate measurement range |
| Incorrect current direction or sign | Circuit equations are set up incorrectly | Unreasonable currents or voltage residuals | Mark arrows and loop directions on the circuit diagram |
| Different meter insertion positions | Circuit conditions change slightly for each measurement | Separately measured currents do not sum exactly | Measure simultaneously or maintain identical conditions |
| Numerical rounding | Errors accumulate during intermediate calculations | Residual may not be exactly zero even theoretically | Keep sufficient significant digits during calculations |
Why the First Law Holds
If the current entering a junction remained greater than the current leaving it, charge would continuously accumulate at the junction. Conversely, if the outgoing current were greater, the charge at the junction would continuously decrease.
In a steady-state DC circuit, charge at the junction does not increase or decrease with time, so the total incoming current equals the total outgoing current.
Why the Second Law Holds
When charge passes through a power source, it receives electrical energy, and when it passes through a resistor, that energy is converted into heat and other forms.
After traversing a closed loop and returning to the starting point, the electric potential must return to its original value. Therefore, the algebraic sum of potential rises and drops is zero.
Meaning of a Negative Current
When setting up circuit equations, current directions may be assumed arbitrarily even when the actual directions are unknown. A negative calculated result does not mean the law failed; it means the actual current flows opposite to the assumed arrow.
Why Measured Sums Do Not Match Exactly
Kirchhoff’s laws hold not only for ideal circuits but also for real circuits. In experiments, however, instrument resolution, internal resistance, source-voltage variation, resistance errors, and other effects cause small residuals when sums are calculated from measured values.
Therefore, rather than simply stating that the residual was not zero, it is important to evaluate it as a percentage of the measured value.
Example of How to Write the Results
A branched circuit with two closed loops sharing a common resistor was constructed, and the current in each branch and voltage across each component were measured.
The current entering junction A was 32.15 mA, the sum of 30.1 mA in the left branch and 2.05 mA in the right branch. The current leaving junction A through the center branch was 32.10 mA. The difference was 0.05 mA, corresponding to approximately 0.16%.
In the left closed loop, the sum of voltage drops across the components was 5.99 V compared with a source voltage of 6.00 V, giving a residual of 0.01 V. The measured currents in each branch generally agreed with the theoretical values.
Points to Connect to the Discussion
- Did the currents entering and leaving the junction agree?
- What were the residual and percentage difference for the first law?
- Did the total EMF and voltage drops agree in each closed loop?
- What was the residual for the second law?
- How closely did theoretical and measured currents agree?
- How did differences between nominal and measured resistor values affect the results?
- Could the internal resistance and terminal-voltage drop of the power source be neglected?
- How did the internal resistances of the ammeter and voltmeter affect the circuit?
- Did circuit conditions change each time a meter was inserted?
- Were signs for current directions and loop traversal handled correctly?
- What does a negative calculated current mean?
- How can disagreement between the laws and measured values be evaluated as measurement error?
Discussion Example
In this experiment, the currents in each branch and the voltages across each component were measured in a branched circuit in which two closed loops shared a common resistor, in order to verify Kirchhoff’s first and second laws.
The current entering junction A was 32.15 mA, consisting of 30.1 mA in the left branch and 2.05 mA in the right branch. The current leaving junction A through the center branch was 32.10 mA.
The difference was 0.05 mA, approximately 0.16% of the center-branch current. Considering instrument resolution and small fluctuations in source voltage, this difference is small, so the total incoming and outgoing currents agreed within experimental error.
This result shows that charge does not accumulate at a junction in steady state and that Kirchhoff’s first law follows from conservation of charge.
In the left loop, the source voltage was 6.00 V while the total voltage drop across the resistive components was 5.99 V, giving a residual of 0.01 V. In the right loop as well, the algebraic sum of EMF and voltage drops was close to zero.
Because the potential rises and drops around each closed loop were nearly equal, Kirchhoff’s second law was satisfied within experimental error. This indicates that the energy supplied by the source to charge equals the energy dissipated in the resistors and other components.
In the theoretical calculation, simultaneous equations were constructed from the first law and the second law for the two loops. The resulting branch currents were approximately 30.4 mA, 2.01 mA, and 32.4 mA, which generally agreed with the measured values.
Possible causes of the differences between theoretical and measured values include deviations of actual resistor values from their nominal values, internal resistance of the sources causing terminal voltage to change under load, and the finite internal resistance of the ammeters and voltmeters.
In particular, an ammeter is inserted in series with a branch, so its internal resistance slightly increases the total branch resistance. As a result, the measured current may be slightly smaller than the value calculated for an ideal circuit without the meter.
A voltmeter has a large but finite internal resistance. When connected in parallel with the measured component, it therefore draws a small current. Depending on where the ammeter is connected, this voltmeter current may also be included in the measured current and can affect verification of the first law.
Wires and terminals also have small resistances and produce voltage drops not shown in the ideal circuit diagram. Poor contacts may cause contact resistance to vary with time, making separately measured currents less likely to sum exactly.
Resistor heating may also have changed resistance during measurement. Because the common branch carries a relatively large current, its power dissipation can be comparatively high and its temperature may rise during prolonged operation.
Current directions may be assumed arbitrarily in the calculations. If a calculated current is negative, it indicates that the actual current flows opposite to the assumed direction. The negative value should therefore not simply be converted to an absolute value as if it were an error; instead, the arrow direction should be reversed in the interpretation.
Measurement accuracy can be improved by using measured resistor values and source terminal voltages under load in the theoretical calculations. It is also desirable to use ammeters with low internal resistance, voltmeters with high internal resistance, and, where possible, measure branch currents simultaneously.
In conclusion, conservation of current at the junction and conservation of voltage around closed loops were confirmed within measurement error, demonstrating that Kirchhoff’s first and second laws hold.
Discussion Example When the First-Law Difference Is Large
A large difference between incoming and outgoing currents may result from changes in source voltage or contact resistance while the currents were measured sequentially rather than simultaneously, changes in circuit resistance each time the ammeter was inserted, or incorrect recording of current directions and signs.
Discussion Example When the Loop-Voltage Residual Is Large
A large deviation of the algebraic sum of loop voltages from zero may result from using the source’s nominal voltage instead of measuring its terminal voltage under load, failing to include voltage drops in wires and contacts, or assigning an incorrect sign due to voltmeter polarity or the chosen loop direction.
Discussion Example When a Calculated Current Is Negative
A negative current in a branch means that the actual current flows opposite to the direction assumed before the calculation. Kirchhoff’s laws allow current directions to be chosen arbitrarily, so a negative result does not by itself indicate a calculation error.
Summary
Kirchhoff’s first law states that the total current entering a junction equals the total current leaving it and is based on conservation of charge.
The second law states that the algebraic sum of potential changes around a closed loop is zero and is based on conservation of energy.
In the discussion, it is important to evaluate current and voltage residuals numerically and relate them to resistor tolerance, internal resistance of sources and meters, wire resistance, heating, and sign conventions.