Physics 物理学

Hall Effect Discussion Example | Hall Voltage, Hall Coefficient, Carrier Density, and Sources of Error

The Hall effect experiment measures the voltage generated in a conductor or semiconductor carrying an electric current when a magnetic field is applied perpendicular to the current. The resulting voltage appears in a direction perpendicular to both the current and the magnetic field.

This voltage is called the Hall voltage. By examining its magnitude and polarity, it is possible to determine whether the main charge carriers in the sample are electrons or holes, and to calculate the Hall coefficient and carrier density.

Under ideal conditions, the Hall voltage is proportional to the sample current and magnetic flux density and inversely proportional to the sample thickness. In actual measurements, however, electrode misalignment, sample temperature changes, nonuniform magnetic fields, and zero-offset voltages can affect the results.

This article assumes an experiment in which a constant current is passed through a thin semiconductor sample and a magnetic field is applied using an electromagnet or permanent magnet. It covers the introduction, safety notes, items to record, sample experimental values, calculations, sources of error, an example results section, and discussion examples.

Note:

This article is a study reference for discussing results obtained in physics experiments at schools, colleges, and universities. The experimental conditions and measured values shown here are illustrative examples and are not actual measurement results.

Electromagnets and coils may carry large currents and become hot. Do not exceed the rated capacity of the power supply, and turn off the power before changing any wiring. Strong magnets may affect electronic devices, magnetic cards, watches, medical devices, and similar equipment. For actual procedures, follow your institution’s laboratory manual and the instructions of your instructor or teaching assistant.

What Is the Hall Effect?

When a carrier with charge q moves at velocity v in a magnetic field with magnetic flux density B, a Lorentz force acts on the carrier.

F = qvB

When the current direction and magnetic-field direction are perpendicular, the carriers are deflected toward one side of the sample. This produces a charge imbalance between the two sides, creating a transverse electric field and potential difference. This potential difference is the Hall voltage.

Hall Voltage

When a current I flows through a sample of thickness d and a magnetic flux density B is applied perpendicular to the current, the Hall voltage is given by:

VH = RHIB/d

Here, RH is the Hall coefficient.

Hall Coefficient

RH = VHd/(IB)

If only one type of carrier is assumed to contribute to electrical conduction, the Hall coefficient is expressed as:

RH = 1/(nq)

In an n-type semiconductor, where electrons are the main carriers, charge q is negative, so the Hall coefficient is also negative. In a p-type semiconductor, where holes are the main carriers, the Hall coefficient is positive.

Carrier Density

The number of carriers per unit volume can be calculated from the absolute value of the Hall coefficient.

n = 1/(|q||RH|)

Use the following value for the elementary charge:

e = 1.602 × 10−19 C

Proportional Relationships

If the sample thickness and Hall coefficient are constant, the Hall voltage follows these relationships:

  • At constant magnetic flux density, the Hall voltage is proportional to the sample current.
  • At constant sample current, the Hall voltage is proportional to the magnetic flux density.
  • For the same material, a thinner sample produces a larger Hall voltage.

Main Items to Record in the Results

  • Sample material and conduction type
  • Sample thickness, width, and length
  • Sample current
  • Excitation current of the electromagnet
  • Magnetic flux density
  • Zero-offset voltage with no magnetic field applied
  • Hall voltage with the magnetic field applied in the positive direction
  • Hall voltage with the magnetic field applied in the reverse direction
  • Hall voltage with current flowing in the positive direction
  • Hall voltage with current flowing in the reverse direction
  • Corrected Hall voltage
  • Graph of Hall voltage versus magnetic flux density
  • Graph of Hall voltage versus sample current
  • Slope of each graph
  • Hall coefficient
  • Sign of the carriers
  • Carrier density
  • Relative error compared with a theoretical or reference value
  • Sample temperature

Example Experimental Conditions

Item Example Condition
Sample n-type semiconductor
Sample thickness d 0.50 mm
Sample current I 10.0 mA
Magnetic flux density B 0–0.50 T
Measurement temperature 25 ℃
Measuring instrument Digital multimeter or microvoltmeter
Reference Hall coefficient −6.25 × 10−4 m3/C
Reference carrier density 1.00 × 1022 m−3

Example Experimental Values

Magnetic Flux Density and Hall Voltage

Example values when the sample current is held constant at 10.0 mA.

Magnetic Flux Density B (T) Measured Value with Positive Magnetic Field (mV) Measured Value with Reversed Magnetic Field (mV) Corrected Hall Voltage (mV)
0.00 0.12 0.12 0.00
0.10 −1.13 1.37 −1.25
0.20 −2.38 2.62 −2.50
0.30 −3.63 3.87 −3.75
0.40 −4.88 5.12 −5.00
0.50 −6.13 6.37 −6.25

The corrected Hall voltage can be obtained from measurements with the magnetic field in opposite directions as follows:

VH = {V(+B) − V(−B)}/2

Sample Current and Hall Voltage

Example values when the magnetic flux density is held constant at 0.40 T.

Sample Current I (mA) Corrected Hall Voltage (mV)
2.0 −1.01
4.0 −2.00
6.0 −3.01
8.0 −4.00
10.0 −5.00
12.0 −5.99

Example Repeated Measurements

Example of five measurements at a magnetic flux density of 0.40 T and sample current of 10.0 mA.

Measurement Hall Voltage (mV)
1 −4.98
2 −5.02
3 −5.01
4 −4.99
5 −5.00
Average −5.00

Calculation Methods

Zero-Offset Correction by Reversing the Magnetic Field

At a magnetic flux density of 0.40 T, suppose the measured value is −4.88 mV for the positive field direction and 5.12 mV for the reverse field direction. Then:

VH = {V(+B) − V(−B)}/2

= {−4.88 − 5.12}/2

= −5.00 mV

The 0.12 mV offset voltage common to both measurements is removed by this calculation.

Slope of the Graph versus Magnetic Flux Density

If the Hall voltage is −1.25 mV at 0.10 T and −6.25 mV at 0.50 T, the slope is:

a = ΔVH/ΔB

= {−6.25 − (−1.25)} × 10−3 / (0.50 − 0.10)

= −1.25 × 10−2 V/T

Calculating the Hall Coefficient from the Graph Slope

The relationship between Hall voltage and magnetic flux density is:

VH = (RHI/d)B

Therefore, the graph slope a is:

a = RHI/d

RH = ad/I

For a slope of −1.25 × 10−2 V/T, sample thickness of 0.50 mm, and sample current of 10.0 mA:

d = 0.50 mm = 5.0 × 10−4 m

I = 10.0 mA = 1.00 × 10−2 A

RH = ad/I

= (−1.25 × 10−2)(5.0 × 10−4)/(1.00 × 10−2)

= −6.25 × 10−4 m3/C

Calculating the Hall Coefficient from a Single Measurement

For a Hall voltage of −5.00 mV, thickness of 0.50 mm, sample current of 10.0 mA, and magnetic flux density of 0.40 T:

RH = VHd/(IB)

= (−5.00 × 10−3)(5.0 × 10−4)/{(1.00 × 10−2)(0.40)}

= −6.25 × 10−4 m3/C

Calculating Carrier Density

n = 1/(e|RH|)

= 1/{(1.602 × 10−19)(6.25 × 10−4)}

= 9.99 × 1021 m−3

≈ 1.00 × 1022 m−3

Determining the Carrier Type

In this example, the Hall coefficient is negative, so the main carriers are negatively charged electrons and the sample can be identified as an n-type semiconductor.

If the Hall coefficient were positive, the main carriers would be holes and the sample would be identified as p-type.

Calculating Relative Error

If the reference value is −6.00 × 10−4 m3/C and the experimental value is −6.25 × 10−4 m3/C, the relative error can be calculated using their absolute values:

Relative error (%) = ||Experimental value| − |Reference value|| / |Reference value| × 100

= |6.25 − 6.00|/6.00 × 100

= 4.17%

Main Sources of Error

Source of Error Effect on Measurement Typical Effect on Results Improvement
Misalignment of Hall electrodes Longitudinal voltage drop is mixed into the measurement A voltage appears even at zero magnetic field Correct by reversing the magnetic field or current
Error in sample thickness measurement Directly affects the calculated Hall coefficient Overestimating thickness increases calculated RH Measure at several points with a micrometer
Nonuniform magnetic flux density The same magnetic field is not applied across the entire sample The proportionality between VH and B breaks down Place the sample at the center of the magnetic poles
Calibration error of the magnetic flux meter B is systematically shifted The Hall coefficient shifts in one direction Use a calibrated magnetic flux meter
Variation in sample current The Hall voltage changes proportionally Measurements scatter Use a constant-current source
Sample heating Carrier density or mobility changes Voltage changes over time Reduce current and measurement time
Thermoelectric voltage A small voltage caused by temperature differences is superimposed An offset remains even when magnetic field or current is zero Measure with reversed polarity and average
Contact resistance Sample current or voltage measurement becomes unstable Reproducibility decreases Ensure secure electrode contact
Voltmeter resolution and noise Small Hall voltages cannot be read accurately Relative error increases at low fields and low currents Use a microvoltmeter and averaging
Magnetic-field direction error The component perpendicular to the sample becomes smaller Hall voltage is lower than the theoretical value Align the sample and field at right angles
Current-direction error The effective perpendicular component becomes smaller Hall voltage decreases Check electrode placement
Magnetic hysteresis B differs even at the same excitation current Values differ between increasing and decreasing field sweeps Measure B directly at each point
Contribution from multiple carrier types The single-carrier model is not valid Density calculated from 1/(nq) differs from the actual situation State the simplifying assumption explicitly
Sample nonuniformity Carrier density differs by location Results vary with measurement position Use a uniform sample and measure at multiple positions

Why Is Hall Voltage Proportional to Magnetic Flux Density?

The Lorentz force acting on carriers moving through a magnetic field is proportional to the magnetic flux density. A stronger magnetic field causes greater carrier deflection, requiring a stronger transverse electric field to balance it. Therefore, the Hall voltage is proportional to magnetic flux density.

Why Is Hall Voltage Proportional to Sample Current?

A larger sample current means that more carriers move per unit time or that their average drift velocity is greater. As a result, the effect of the Lorentz force becomes larger and the Hall voltage increases.

Why Does the Polarity Change When the Magnetic Field or Current Is Reversed?

The direction of the Lorentz force depends on the carrier velocity, magnetic-field direction, and sign of the charge. Reversing either the magnetic field or the current reverses the direction of the force on the carriers, so the Hall-voltage polarity also reverses.

If both the magnetic field and current are reversed at the same time, the Lorentz-force direction returns to its original direction, so the Hall-voltage polarity also remains the same as before.

Why Measure with the Magnetic Field Reversed?

If the Hall electrodes are not positioned exactly opposite one another, part of the longitudinal voltage drop along the sample is mixed into the Hall-voltage measurement. This unwanted voltage does not change sign when the magnetic field is reversed, whereas the true Hall voltage does.

Therefore, subtracting measurements made with positive and negative magnetic fields and dividing by two removes magnetic-field-independent offset components.

Why Is the Hall Effect Easier to Measure in Semiconductors Than in Metals?

The magnitude of the Hall coefficient is inversely proportional to carrier density. Semiconductors generally have lower carrier densities than metals, so under the same current, magnetic flux density, and sample thickness, semiconductors tend to produce larger Hall voltages.

Example of How to Write the Results

A current of 10.0 mA was passed through a 0.50 mm-thick n-type semiconductor sample, and the Hall voltage was measured while applying a magnetic field from 0 to 0.50 T.

The corrected Hall voltage changed from −1.25 mV at 0.10 T to −3.75 mV at 0.30 T and −6.25 mV at 0.50 T, showing an approximately linear dependence on magnetic flux density.

The slope of the Hall-voltage versus magnetic-flux-density graph was −1.25 × 10−2 V/T. From this slope, the Hall coefficient was calculated as −6.25 × 10−4 m3/C and the carrier density as 1.00 × 1022 m−3.

Points to Connect to the Discussion

  • Was the Hall voltage proportional to magnetic flux density?
  • Was the Hall voltage proportional to sample current?
  • Did the graph form a straight line through the origin?
  • Did reversing the magnetic field reverse the Hall-voltage polarity?
  • Did reversing the current reverse the Hall-voltage polarity?
  • Why was a voltage measured even when the magnetic field was zero?
  • Did magnetic-field reversal correction remove the offset?
  • Could the carrier type be identified from the sign of the Hall coefficient?
  • Was the calculated carrier density reasonable?
  • How much did sample-thickness measurement error affect the result?
  • Could sample heating or temperature changes be neglected?
  • Was there any magnetic-field nonuniformity or sample-position error?
  • Was the assumption of a single-carrier model appropriate?

Discussion Example

In this experiment, a constant current was passed through a 0.50 mm-thick n-type semiconductor sample, and the Hall voltage generated when a magnetic field was applied perpendicular to the sample surface was measured.

With the sample current held constant at 10.0 mA and the magnetic flux density varied from 0.10 T to 0.50 T, the corrected Hall voltage changed almost linearly from −1.25 mV to −6.25 mV.

The graph of Hall voltage versus magnetic flux density was approximately linear, agreeing with the theoretical relationship VH = RHIB/d, which predicts that Hall voltage is proportional to magnetic flux density.

When the magnetic flux density was held constant at 0.40 T and the sample current was varied, the Hall voltage was also approximately proportional to current. These results confirm that Hall voltage is proportional to both magnetic flux density and sample current.

When the magnetic field was reversed, the sign of the measured voltage also reversed. This occurs because reversing the magnetic field reverses the Lorentz force acting on the carriers, which reverses the direction of charge separation within the sample.

Even with no magnetic field applied, a voltage of approximately 0.12 mV was measured. A likely cause is that the Hall-voltage electrodes were not positioned at exactly the same longitudinal location, allowing part of the voltage drop along the sample to enter the measurement.

To correct for this effect, the difference between measurements with positive and negative magnetic fields was divided by two. Because the magnetic-field-independent offset does not change sign while the true Hall voltage does, this method removes the offset component.

The slope of the Hall-voltage versus magnetic-flux-density graph was −1.25 × 10−2 V/T. Using this value together with a sample thickness of 0.50 mm and sample current of 10.0 mA, the Hall coefficient was calculated as −6.25 × 10−4 m3/C.

Because the Hall coefficient was negative, the dominant charge carriers were identified as negatively charged electrons, indicating that the sample was an n-type semiconductor.

Assuming that only one type of carrier contributes to conduction and using n = 1/(e|RH|), the carrier density was calculated to be approximately 1.00 × 1022 m−3.

Possible causes of differences between theoretical and experimental values include errors in measuring sample thickness, nonuniform magnetic flux density, variations in sample current, electrode misalignment, contact resistance, and the resolution of the microvoltmeter.

In particular, because the calculated Hall coefficient is proportional to sample thickness, relative error in the thickness measurement directly contributes to relative error in the Hall coefficient. For thin samples, even a small thickness-reading error may be significant, so measurements should be taken at several points and averaged.

Increasing the sample current increases the Hall voltage, but it also increases Joule heating. In semiconductors, carrier density and mobility depend on temperature, so significant heating may violate the assumption that the Hall coefficient remains constant.

If the magnetic flux density between the pole pieces is not uniform, or if the sample is displaced from the center of the poles, the value measured by the magnetic-flux meter may differ from the average field actually experienced by the sample. To reduce this effect, the sample should be accurately centered and the magnetic flux density should be measured at the sample position.

Furthermore, in real semiconductors more than one type of carrier may contribute to conduction. In such cases, the simple relationship RH = 1/(nq) is not strictly valid. The carrier density calculated here should therefore be treated as an approximate value based on the single-carrier model.

Measurement accuracy can be improved by taking measurements with both positive and negative magnetic-field and current polarities and averaging them, keeping the sample temperature constant, using a constant-current source, and measuring sample thickness at multiple points.

These results experimentally confirm that Hall voltage is proportional to magnetic flux density and sample current, and that its polarity and magnitude can be used to determine the Hall coefficient, carrier type, and carrier density.

Discussion Example When the Graph Does Not Pass Through the Origin

If the Hall-voltage versus magnetic-flux-density graph does not pass through the origin, possible causes include longitudinal voltage mixed into the measurement due to Hall-electrode misalignment, thermoelectric voltage between contacts, and zero-offset error of the voltmeter. A magnetic-field-independent offset can be corrected by subtracting measurements taken with positive and negative fields and dividing by two.

Discussion Example When the High-Field Data Deviate from Proportionality

If the Hall voltage deviates from a linear relationship at high magnetic fields, possible causes include a difference between the magnetic-flux measurement position and the sample position, magnetic saturation of the electromagnet, sample heating, and contributions from multiple carrier types. The data should be analyzed using the magnetic flux density measured directly at each measurement point rather than the excitation current alone.

Discussion Example When the Carrier Sign Differs from Expectations

If the sign of the Hall coefficient differs from the expected sign, the polarity of the Hall-voltage terminals or the definitions of the current and magnetic-field directions may have been reversed. Check the coordinate directions of the apparatus and the positive and negative voltmeter terminals, then verify that reversing either the magnetic field or current reverses the voltage polarity.

Discussion Example When Measurements Show Large Scatter

Large scatter in the measured values may be caused by variations in sample current, poor electrode contact, electrical noise entering the small-voltage measurement, or changes in sample temperature. Short, shielded wiring and averaging multiple measurements can help improve reproducibility.

Summary

In the Hall effect, applying a magnetic field perpendicular to a current-carrying sample generates a Hall voltage in a direction perpendicular to both the current and the magnetic field.

The Hall voltage is proportional to magnetic flux density and sample current and inversely proportional to sample thickness. The sign of the Hall coefficient can identify whether the dominant carriers are electrons or holes, while its magnitude can be used to calculate carrier density.

In the discussion, it is important to connect the proportional relationships, polarity reversal with magnetic-field reversal, zero-offset correction, Hall coefficient, carrier density, sample thickness, temperature changes, magnetic-field nonuniformity, and the assumptions of the single-carrier model.